Humidity Indicator Card
A humidity indicator card (HIC) is a card on which a moisture-sensitive chemical is impregnated such that it will change color when the indicated relative humidity is exceeded.
Interteck supplies a full line of Humidity Indicating Cards (HIC) which allows a low cost method of indicating humidity conditions
for various types of barrier packaging, including MIL Spec (MIL-I-8835)
Applications. The 30%, 40%, 50% HIC card complies with MS 20003-2
And the 5%, 10%, 15% complies with JEDEC Standard 033.
The 5%, 10%, 60% card complies with JEDEC Standard
Quantity per can:
5%-10%-15% – 125 cards/can
10%-20%-30% – 125 cards/can
30%-40%-50% – 125 cards/can
5%-10%-60% – 125 cards/can
10% – 60% – 200 cards/can
8% single spot – 500 cards/can
Humidity indicator cards are impregnated with a solution of cobalt chloride that has been carefully mixed to change color from blue through various shades of magenta – red, to a pink. These cards are not precision indicators. However, they are very good at telling you the maximum possible humidity in a container. For example if all of the dots are deep blue on a card which is a 10%- 60% card than you can be assured that the humidity in that container is below 10%. This is very important for some products and household items because as long as the humidity is below 40%, basic corrosion (rust) will not occur. Neither will mildew or mold in clothing or paper products. Finally, all sophisticated electronics: video cameras, computers, SLR cameras, sophisticated instruments etc. enjoy a much longer and more reliable life if they are maintained at a very low relative humidity. For example, at the bottom of this page are cards that were developed specifically for the electronics (computer chips) industry. These companies require that the humidity in their shipping packages be below 10% and as of the guidelines established in the fall of 1999 are striving to maintain humidity below 5%.
You can compare the color change in this picture
HIC card on the top is outside the bag and shows the humidity is more than 50%. The card sealed in the clear bag along with small packets shows the humidity inside the bag is lower than 10% (all spots are blue).
This card is reading that the humidity is certainly above 10%, probably around 20%
This card is reading that the humidity is somewhere around 50%
Humidity Indicator Cards:
The HIC should comply with MIL-I-8835 and, at a minimum, have three color dots with sensitivity values of 30% RH, 40% RH, and 50% RH.
PCB Dry Packaging:
Proper packaging of the lead-free compatible PCB is critical. The packaging system must be carefully developed by the PCB fabricator to protect the PCB from atmospheric moisture that may enter the packaging materials by diffusion. The packaging system should be developed to offer a shelf life of 12 months at ≤40°C and 90% RH.
Desiccant:
- Proper selection of the desiccant should include consideration of the environmental conditions during shipping as these may affect the function of specific desiccant materials.
- Check with your desiccant supplier for moisture capacity capability in ´units´.
PCB’s should be vacuum packed in a width adequate desiccant and humidity indicator card.
- PCB’s should be packaged immediately after final inspection. The exposure time for the PCB prior to packaging should be minimized to eliminate the potential for moisture/volatile absorption as defined above.
- Moisture Barrier bags must be hermetically heat sealed with an adequate seal width per manufacturers recommendations to ensure proper bag performance.
- One humidity indicator card should be placed in the bag with the PCB’s.
- The HIC should be placed adjacent to the desiccant, not on top of the packet(s).
- The amount of desiccant should provide protection for a minimum of one year.
- Other packaging materials used in the bag will also have a moisture content. The moisture/volatile content of these materials must be considered in calculating the number of desiccant packets to be used.
Determining Desiccant Requirements:
To determine the proper quantity of desiccant ´units´ to be used in the bag, use the following formula.
Units=(0.231 x Bag Surface Area x Bag WVTR x Months) / Moisture Capacity
Example
- 8″ x 10″ MBB x 2 sides = 160 in²
- 0.02 WVTR
- 12 months storage
- At 40% MIH, the moisture capacity = 6.2 g/unit
Units=(0.231 x 160 in² x 0.02 WVTR x 13 months) / (6.2g / unit)
Units = 1.4 desiccants ≈ 2 units
The 30%, 40%, and 50% cards comply specifically with MS 20003-2, while the 5%, 10%, and 15% cards are cleared for use with JEDEC Standard 033.
- Indicate humidity conditions in various types of packaging.
- Often used in conjunction with a desiccant.
- Allow instant visual verification of product / environment.
- Approved for MIL – I – 8835 applications.
- Low Cost.
- Spots turn from Blue to Pink to indicate humidity levels.
Showing the single result
Showing the single result